Skip to main content

Breadcrumb

  1. Home

Endorsed

Excess days in acute care (EDAC) after hospitalization for heart failure (HF)

  • The measure assesses days spent in acute care within 30 days of discharge from an inpatient hospitalization for HF to provide a patient-centered assessment of the post-discharge period. This measure is intended to capture the quality of care transitions provided to discharged patients who had a HF hospitalization by collectively measuring a set of adverse acute care outcomes that can occur post-discharge: emergency department (ED) visits, observation stays, and unplanned readmissions at any time during the 30 days post-discharge.

    CBE ID
    2880

Excess days in acute care (EDAC) after hospitalization for pneumonia

  • This measure assesses days spent in acute care within 30 days of discharge from an inpatient hospitalization for pneumonia, including aspiration pneumonia or for sepsis (not severe sepsis) with a secondary discharge diagnosis of pneumonia coded in the claim as present on admission (POA) and no secondary diagnosis of severe sepsis coded as POA.

    CBE ID
    2882

Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults (Clinician Group Level)

  • This electronic clinical quality measure (eCQM) provides a standardized method for monitoring the performance of diagnostic CT to discourage unnecessarily high radiation doses, a risk factor for cancer, while preserving image quality. It is expressed as a percentage of eligible CT exams that are out-of-range based on having either excessive radiation dose or inadequate image quality, relative to evidence-based thresholds based on the clinical indication for the exam.

    CBE ID
    3662e

Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults (Clinician Level)

  • This electronic clinical quality measure (eCQM) provides a standardized method for monitoring the performance of diagnostic CT to discourage unnecessarily high radiation doses, a risk factor for cancer, while preserving image quality. It is expressed as a percentage of eligible CT exams that are out-of-range based on having either excessive radiation dose or inadequate image quality, relative to evidence-based thresholds based on the clinical indication for the exam.

    CBE ID
    3633e

Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults (Facility Level)

  • This electronic clinical quality measure (eCQM) provides a standardized method for monitoring the performance of diagnostic CT to discourage unnecessarily high radiation doses, a risk factor for cancer, while preserving image quality. It is expressed as a percentage of eligible CT exams that are out-of-range based on having either excessive radiation dose or inadequate image quality, relative to evidence-based thresholds based on the clinical indication for the exam.

    CBE ID
    3663e

Falls: Screening, Risk-Assessment, and Plan of Care to Prevent Future Falls

  • This is a clinical process measure that assesses falls prevention in older adults. The measure has three rates:

    A) Screening for Future Fall Risk:
    Percentage of patients aged 65 years and older who were screened for future fall risk at least once within 12 months



    B) Falls Risk Assessment: 
    Percentage of patients aged 65 years and older with a history of falls who had a risk assessment for falls completed within 12 months

    C) Plan of Care for Falls: 

    CBE ID
    0101

Family Experiences with Coordination of Care (FECC) -3: Care coordinator helped to obtain community services

  • The Family Experiences with Coordination of Care (FECC) Survey was developed to gather information about the quality of care coordination being received by children with medical complexity (CMC) over the previous 12 months. The FECC Survey is completed by English- and Spanish-speaking caregivers of CMC aged 0-17 years with at least 4 medical visits in the previous year, and it includes all of the information needed to score 20 separate and independent quality measures, a sub-set of 8 of which are included in this submitted measure set.

    CBE ID
    2843

Family Experiences with Coordination of Care (FECC) -5: Care coordinator asked about concerns and health

  • The Family Experiences with Coordination of Care (FECC) Survey was developed to gather information about the quality of care coordination being received by children with medical complexity (CMC) over the previous 12 months. The FECC Survey is completed by English- and Spanish-speaking caregivers of CMC aged 0-17 years with at least 4 medical visits in the previous year, and it includes all of the information needed to score 20 separate and independent quality measures, a sub-set of 8 of which are included in this submitted measure set.

    CBE ID
    2844

Family Experiences with Coordination of Care (FECC) -7: Care coordinator assisted with specialist service referrals

  • The Family Experiences with Coordination of Care (FECC) Survey was developed to gather information about the quality of care coordination being received by children with medical complexity (CMC) over the previous 12 months. The FECC Survey is completed by English- and Spanish-speaking caregivers of CMC aged 0-17 years with at least 4 medical visits in the previous year, and it includes all of the information needed to score 20 separate and independent quality measures, a sub-set of 8 of which are included in this submitted measure set.

    CBE ID
    2845

Family Experiences with Coordination of Care (FECC) -9: Appropriate written visit summary content

  • The Family Experiences with Coordination of Care (FECC) Survey was developed to gather information about the quality of care coordination being received by children with medical complexity (CMC) over the previous 12 months. The FECC Survey is completed by English- and Spanish-speaking caregivers of CMC aged 0-17 years with at least 4 medical visits in the previous year, and it includes all of the information needed to score 20 separate and independent quality measures, a sub-set of 8 of which are included in this submitted measure set.

    CBE ID
    2847